MProbe 60 - automated film thickness mapping

A complete turnkey system for R&D centers and small manufacturing, combining thickness and n, k measurement with mapping automation and small-spot capability. Measure from 1 nm to 2 mm, including multilayer filmstacks.

Overview

MProbe® 60 is a turnkey mapping system used by leading R&D and nanotechnology centers worldwide. It pairs the MProbe measurement engine with a motorized stage and mapping software, so you can characterize thickness and optical constants point-by-point across a full sample. Models differ by spectrometer wavelength range and resolution, which set the measurable thickness range.

Why MProbe 60

  • Turnkey mapping automation - flexible and modular, ready to run out of the box.
  • Precision - < 0.01 nm or 0.01%.
  • 500+ material library for complex, multilayer stacks.
  • Integrated camera & imaging - pinpoint the measurement location and display results directly on the image.
  • Powerful software - TFCompanion™ with unlimited layers, backside-reflectance, roughness and dullness support.

Configurations & thickness ranges

ModelWavelengthThickness range
Vis-MAP400–1000 nm10 nm–75 µm
UVVisSR-MAP200–1100 nm1 nm–75 µm
VisHR-MAP700–1100 nm1–400 µm
NIR-MAP900–1700 nm50 nm–85 µm
UVVisNIR-MAP200–1700 nm1 nm–85 µm
NIRHR-MAP1500–1550 nm10–1800 µm (glass), 4–400 µm (Si)

Spot sizes down to 2 µm are possible with a 100× objective and 200 µm core fiber; 20 µm with a 40× all-reflective objective and 400 µm fiber.

Options

  • XY mapping stage - motorized with controller and mapping software; 150×150 mm, 200×200 mm or 300×300 mm. Step size 0.5 µm, repeatability 1 µm. One stage must be selected.
  • Transmission option - attachment for transmittance measurement, including a quartz stage insert, fiber optics, collimator optics and a 45° mirror cube, matched to the system wavelength range.
  • LWD objectives - Visible and Vis-NIR (2× through 100×) plus all-mirror Cassegrain achromats (10×, 15×, 20×) covering 190–1700 nm.

What's in the box

  • Main unit (spectrometer and light source)
  • Solid platform with motorized mapping stage and controller
  • Microscope tube on a motorized z-axis stage, or a bracket with standard lens (configuration dependent)
  • Fiber-optic reflectance probe
  • TFCompanion-RA software, USB license dongle, distribution media and User Guide
  • Calibration set and black absorber; test sample (200 nm Si oxide or PET film)

Need thickness maps across a full wafer?

Tell us your sample size and film stack - we'll configure the right stage, objectives and spectrometer.

Request a Quote